參考文獻 |
[1] T. Jianxuan and L. Jenshan, "Respiration harmonics cancellation for Accurate Heart Rate measurement in non-contact vital sign detection," in Microwave Symposium Digest (IMS), 2013 IEEE MTT-S International, 2013, pp. 1-3.
[2] L. Changzhi, V. M. Lubecke, O. Boric-Lubecke, and L. Jenshan, "A Review on Recent Advances in Doppler Radar Sensors for Noncontact Healthcare Monitoring," Microwave Theory and Techniques, IEEE Transactions on, vol. 61, pp. 2046-2060, 2013.
[3] C. Li and J. Lin, "Recent advances in Doppler radar sensors for pervasive healthcare monitoring," in 2010 Asia-Pacific Microwave Conference, 2010, pp. 283-290.
[4] 陳威志, "低功耗非接觸式之心肺檢測與人員定位系統," 碩士, 電機工程研究所, 國立中正大學, 嘉義縣, 2014.
[5] G. Wang, C. Gu, T. Inoue, and C. Li, "A Hybrid FMCW-Interferometry Radar for Indoor Precise Positioning and Versatile Life Activity Monitoring," IEEE Transactions on Microwave Theory and Techniques, vol. 62, pp. 2812-2822, 2014.
[6] J. C. Lin, "Microwave sensing of physiological movement and volume change: A review," Bioelectromagnetics, vol. 13, pp. 557-565, 1992.
[7] K. M. Chen, D. Misra, H. Wang, H. R. Chuang, and E. Postow, "An X-Band Microwave Life-Detection System," IEEE Transactions on Biomedical Engineering, vol. BME-33, pp. 697-701, 1986.
[8] W. Fu-Kang, H. Tzyy-Sheng, P. Kang-Chun, J. Je-Kuan, L. Jian-Yu, and C. Cheng-Chung, "Detection of Concealed Individuals Based on Their Vital Signs by Using a See-Through-Wall Imaging System With a Self-Injection-Locked Radar," Microwave Theory and Techniques, IEEE Transactions on, vol. 61, pp. 696-704, 2013.
[9] E. Yavari and O. Boric-Lubecke, "Channel Imbalance Effects and Compensation for Doppler Radar Physiological Measurements," IEEE Transactions on Microwave Theory and Techniques, vol. 63, pp. 3834-3842, 2015.
[10] J. Li, L. Liu, Z. Zeng, and F. Liu, "Advanced Signal Processing for Vital Sign Extraction With Applications in UWB Radar Detection of Trapped Victims in Complex Environments," IEEE Journal of Selected Topics in Applied Earth Observations and Remote Sensing, vol. 7, pp. 783-791, 2014.
[11] G. Wang, J. M. Mu, x00F, F. oz, C. Gu, C. Li, et al., "Application of Linear-Frequency-Modulated Continuous-Wave (LFMCW) Radars for Tracking of Vital Signs," IEEE Transactions on Microwave Theory and Techniques, vol. 62, pp. 1387-1399, 2014.
[12] J. Fuchs, K. D. Ward, M. P. Tulin, and R. A. York, "Simple techniques to correct for VCO nonlinearities in short range FMCW radars," in 1996 IEEE MTT-S International Microwave Symposium Digest, 1996, pp. 1175-1178 vol.2.
[13] L. Changzhi and L. Jenshan, "Random Body Movement Cancellation in Doppler Radar Vital Sign Detection," Microwave Theory and Techniques, IEEE Transactions on, vol. 56, pp. 3143-3152, 2008.
[14] H. R. Chuang, H. C. Kuo, F. L. Lin, T. H. Huang, C. S. Kuo, and Y. W. Ou, "60-GHz Millimeter-Wave Life Detection System (MLDS) for Noncontact Human Vital-Signal Monitoring," IEEE Sensors Journal, vol. 12, pp. 602-609, 2012.
[15] L. Chioukh, H. Boutayeb, D. Deslandes, and K. Wu, "Noise and Sensitivity of Harmonic Radar Architecture for Remote Sensing and Detection of Vital Signs," IEEE Transactions on Microwave Theory and Techniques, vol. 62, pp. 1847-1855, 2014.
[16] W. Ping-Hsun, J. Je-Kuan, L. Chien-Jung, H. Tzyy-Sheng, and H. Powen, "Phase- and Self-Injection-Locked Radar for Detecting Vital Signs with Efficient Elimination of DC Offsets and Null Points," Microwave Theory and Techniques, IEEE Transactions on, vol. 61, pp. 685-695, 2013.
[17] P. Byung-Kwon, O. Boric-Lubecke, and V. M. Lubecke, "Arctangent Demodulation With DC Offset Compensation in Quadrature Doppler Radar Receiver Systems," Microwave Theory and Techniques, IEEE Transactions on, vol. 55, pp. 1073-1079, 2007.
[18] A. Lazaro, D. Girbau, R. Villarino, and A. Ramos, "Vital signs monitoring using impulse based UWB signal," in 2011 41st European Microwave Conference, 2011, pp. 135-138.
[19] S. Wang, A. Pohl, T. Jaeschke, M. Czaplik, M. Köny, S. Leonhardt, et al., "A novel ultra-wideband 80 GHz FMCW radar system for contactless monitoring of vital signs," in 2015 37th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), 2015, pp. 4978-4981.
[20] R. Lingyun, W. Haofei, K. Naishadham, Q. Liu, and A. E. Fathy, "Non-invasive detection of cardiac and respiratory rates from stepped frequency continuous wave radar measurements using the state space method," in 2015 IEEE MTT-S International Microwave Symposium, 2015, pp. 1-4.
[21] J. Tu and J. Lin, "Fast Acquisition of Heart Rate in Noncontact Vital Sign Radar Measurement Using Time-Window-Variation Technique," IEEE Transactions on Instrumentation and Measurement, vol. 65, pp. 112-122, 2016.
[22] A. Singh and V. M. Lubecke, "Respiratory Monitoring and Clutter Rejection Using a CW Doppler Radar With Passive RF Tags," IEEE Sensors Journal, vol. 12, pp. 558-565, 2012.
[23] M. Baboli, O. Boric-Lubecke, and V. Lubecke, "A new algorithm for detection of heart and respiration rate with UWB signals," in Engineering in Medicine and Biology Society (EMBC), 2012 Annual International Conference of the IEEE, 2012, pp. 3947-3950.
[24] J. H. Cheng, J. F. Yeh, H. Y. Yang, J. H. Tsai, J. Lin, and T. W. Huang, "40-GHz vital sign detection of heartbeat using synchronized motion technique for respiration signal suppression," in Microwave Conference (EuMC), 2012 42nd European, 2012, pp. 21-24.
[25] J. M. Mu, F. oz, G. Wang, C. Li, G. R, and G. mez, "Mitigation of stationary clutter in vital-sign-monitoring linear-frequency-modulated continuous-wave radars," IET Radar, Sonar & Navigation, vol. 9, pp. 138-144, 2015.
[26] N. E. Huang, Z. Shen, S. R. Long, M. C. Wu, H. H. Shih, Q. Zheng, et al., "The empirical mode decomposition and the Hilbert spectrum for nonlinear and non-stationary time series analysis," in Proceedings of the Royal Society of London A: Mathematical, Physical and Engineering Sciences, 1998, pp. 903-995.
[27] W. Hu, Z. Zhao, Y. Wang, H. Zhang, and F. Lin, "Noncontact Accurate Measurement of Cardiopulmonary Activity Using a Compact Quadrature Doppler Radar Sensor," IEEE Transactions on Biomedical Engineering, vol. 61, pp. 725-735, 2014.
[28] W. David, "FMCW MMW Radar for Automotive Longitudinal Control," California PATH Research Report, 1997.
[29] L. Changzhi and L. Jenshan, "Complex signal demodulation and random body movement cancellation techniques for non-contact vital sign detection," in Microwave Symposium Digest, 2008 IEEE MTT-S International, 2008, pp. 567-570.
[30] C. Li, Y. Xiao, and J. Lin, "Experiment and Spectral Analysis of a Low-Power Ka-Band Heartbeat Detector Measuring From Four Sides of a Human Body," IEEE Transactions on Microwave Theory and Techniques, vol. 54, pp. 4464-4471, 2006.
[31] M.-C. Wu and C.-K. Hu, "Empirical mode decomposition and synchrogram approach to cardiorespiratory synchronization," Physical Review E, vol. 73, p. 051917, 2006.
[32] Visual Signal Overview from website. Available: http://www.ancad.com/VisualSignal/overview.html
[33] (2007). Dielectric properties of body issues. Available: http://niremf.ifac.cnr.it/tissprop/htmlclie/htmlclie.php
[34] R. F. Harrinton, Time Harmonic Electromagnetic Fields, 1961.
[35] C. Li, X. Yu, C. M. Lee, D. Li, L. Ran, and J. Lin, "High-Sensitivity Software-Configurable 5.8-GHz Radar Sensor Receiver Chip in 0.13-um CMOS for Noncontact Vital Sign Detection," IEEE Transactions on Microwave Theory and Techniques, vol. 58, pp. 1410-1419, 2010.
[36] VCO HMC431LP4E [Data Sheet]. Available: http://www.analog.com/media/en/technical-documentation/data-sheets/hmc431.pdf
[37] Power Splitter (1 to 4) EPS-60C data sheet. Available: http://www.e-channel.cn/cn/upLoad/down/month_1504/201504021411053398.pdf
[38] Power Amplifier ZRON-8G+. Available: https://www.minicircuits.com/pdfs/ZRON-8G+.pdf
[39] LNA HMC902LP3E [Data Sheet]. Available: http://www.analog.com/media/en/technical-documentation/data-sheets/hmc902.pdf
[40] LNA HMC392LC4 [Data Sheet]. Available: http://www.analog.com/media/en/technical-documentation/data-sheets/hmc392lc4.pdf
[41] Gain Block HMC311SC70 [Data Sheet]. Available: http://www.analog.com/media/en/technical-documentation/data-sheets/hmc311sc70.pdf
[42] I/Q Mixer HMC525LC4 [Data Sheet]. Available: http://www.analog.com/media/en/technical-documentation/data-sheets/hmc525.pdf
[43] NI DAQ-6361 Available: http://www.ni.com/pdf/manuals/374650c.pdf
[44] Laser Displacement Sensor Available: http://www.bosch-pt.com.tw/tw/zh/laser-measure-glm-30-131500-06010725k0.html
[45] Biopac MP 36 for ECG aquisition system Available: https://www.biopac.com/product/upgrade-to-mp36-system/
[46] H. Zhang, S. Li, X. Jing, P. Zhang, Y. Zhang, T. Jiao, et al., "The Separation of the Heartbeat and Respiratory Signal of a Doppler Radar Based on the LMS Adaptive Harmonic Cancellation Algorithm," in 2013 Sixth International Symposium on Computational Intelligence and Design, 2013, pp. 362-364.
|