進階搜尋


   電子論文尚未授權公開,紙本請查館藏目錄
(※如查詢不到或館藏狀況顯示「閉架不公開」,表示該本論文不在書庫,無法取用。)
系統識別號 U0026-0608201913412300
論文名稱(中文) 藉由水工模型探討延性鑄鐵管襯裡之摩擦係數研究
論文名稱(英文) Friction Coefficient Comparison between Different Ductile Iron Pipe Inner Linings by Hydraulic Model Test
校院名稱 成功大學
系所名稱(中) 水利及海洋工程學系碩士在職專班
系所名稱(英) Department of Hydraulics & Ocean Engineering (on the job class)
學年度 107
學期 2
出版年 108
研究生(中文) 張竣超
研究生(英文) Chun-Chao Chang
學號 n87051034
學位類別 碩士
語文別 中文
論文頁數 72頁
口試委員 指導教授-呂珍謀
口試委員-李明靜
口試委員-王裕民
口試委員-詹勳全
中文關鍵字 自來水  管材  襯裡  摩擦阻力 
英文關鍵字 Tap water  Pipe material  Inner lining  Friction resistance 
學科別分類
中文摘要 管道的阻力特性一般用摩擦阻力係數來描述,而大部分水利工程師採用C值摩擦阻力係數概算可能的水頭損失,但一般教科書、文獻中所查得之C值僅依據管路材料進行概估,實際之阻力值仍不確定。現階段台灣地區自來水事業採用公共工程施工綱要規範第02514章─自來水用延性鑄鐵管件,針對管內壁塗裝可使用“卜特蘭水泥第 II 型、延性鑄鐵管及管件內面用環氧樹脂粉體塗裝”。為了解管路之實際之摩擦阻力係數,本研究採用一般坊間所生產之水泥砂漿襯裡管路,與新研發之環氧樹脂粉體塗裝襯裡管路進行試驗,以了解新型環氧樹脂塗裝襯裡管路實際摩擦阻力係數,以及與水泥砂漿襯裡管路之差異性。
由結果可知水泥砂漿襯裡之C值介於137.5 ~ 147.0之間,而環氧樹脂粉體塗裝襯裡之C值介於147.5 ~ 149.0之間,其摩擦阻力較低。水泥砂漿襯裡之f值介於0.0151 ~0.0170之間,環氧樹脂粉體塗裝襯裡之f值介於0.0132 ~0.0170之間,隨雷諾數而變化,於3 m/s流速下差異百分比最高達到12.3%。查詢Moody圖進行分析可知300 mm管徑之水泥砂漿襯裡管路之e值為0.03 mm,接近光滑混凝土(e = 0.025 mm)之值,而310 mm管徑之環氧樹脂粉體塗裝襯裡管路之e值為0.0031 mm,已接近PVC等光滑管路(e = 0.0025 mm)之表現。
由分析結果可知兩種管路之C值並非為定值,會隨溫度、流速產生變化,但與雷諾數之關聯性又不明顯,以其進行分析將產生較大誤差,於工程上僅適用於現場即時概略估算之用。而Darcy-Weisbach公式之f值則與雷諾數、相對粗糙度、溫度明確相關。且在f值已知的條件下,利用公式亦可快速的計算摩擦損失,亦相當方便。爰此,未來自來水事業機構進行規劃設計、水理分析時,採用Hazen-Williams equation提高安全係數設計確實較為簡便,但建議對應不同設計條件應再以Darcy-Weisbach公式進行評估覆核,以確保設計之準確性,另在智慧管網之應用,建議以Darcy-Weisbach公式計算評估,較為適當與準確。
英文摘要 Normally, the friction characteristics of ductile pipe is described with friction coefficient. Most hydraulic engineers estimate water head loss by C number friction coefficient. However, C number data in textbook and literature usually is estimated by ductile pipe material. Actual friction is not certain. For investigating friction coefficient of ductile pipe, this research performs friction coefficient comparison between civilian produced cement mortar and recently developed epoxy resin powder ductile iron pipe inner linings with experiments.
The experimental results show that the C number of cement mortar inner lining is between 137.5 and 147.0, and epoxy resin powder inner lining, whose C number is between 137.5 and 147.0, has lower friction. The f number of cement mortar inner lining is between 0.0151 and 0.0170, and the f number of epoxy resin powder inner lining is between 0.0132 and 0.0170. The f number which varied with Reynold number has maximum variation of 12.3% when flow velocity is 3m/s. By Moody diagram, the e number of 300mm diameter ductile iron pipe with cement mortar inner lining is 0.03mm and similar to the e number of smooth concrete (e = 0.025mm); the e number of 300mm diameter ductile iron pipe with epoxy resin inner lining is 0.0031mm and similar to the e number of smooth PVC pipe (e = 0.0025mm).
The analysis show that the C numbers of the tubes are not constant and varied with temperature and flow velocity. Since their relationship with Reynolds number is not obvious, C number analysis produces larger error and is only useful for in-situ, quick and rough estimation. The f number derived by Darcy-Weisbach equation is certainly varied with Reynolds number, relative roughness and temperature. Calculating friction loss by deriving f number is quick and easy. Hence, future design plan and hydrological analysis performed by tap water company should ensure safety parameter margin by Hazen-Williams equation. The examination with Darcy-Weisbach equation under different conditions should be performed for better accuracy of design. The intelligent pipe network design should be evaluated by Darcy-Weisbach equation for better accuracy.
Keywords: Tap water, Pipe material, Inner lining, Friction resistance
論文目次 摘要 I
EXTENDED ABSTRACT III
致謝 IX
目錄 X
表目錄 XII
圖目錄 XIII
第一章 緒論 1
1.1研究背景與動機 1
1.2 研究目的與範圍 1
1.2.1 研究目的 1
1.2.2研究範圍 2
1.3研究方法 3
1.4論文架構 3
第二章 相關理論與文獻回顧 5
2.1 水力分析理論 5
2.2自來水常用管材 10
2.3試驗管材選定 18
2.4試驗流速 20
第三章 試驗方法與步驟 21
3.1實驗裝置工作原理 21
3.2試驗設備 22
3.3試驗流程 31
第四章 試驗結果分析與討論 35
4.1管壓、溫度值 35
4.2壓力損失梯度分析 38
4.2.1水泥砂漿襯裡之水頭損失 38
4.2.2環氧樹脂粉體塗裝襯裡之水頭損失 43
4.3流速影響 46
4.4異常壓力值 49
4.4.1 異常壓力點 49
4.4.2 異常壓力值分析 49
4.4.3 異常原因探討 50
4.5水泥砂漿襯裡與環氧樹脂粉體塗裝襯裡之試驗結果分析 53
4.5.1兩種襯裡材質C值分析 55
4.5.2兩種襯裡材質f值分析 57
第五章 結論與建議 68
5.1結論 68
5.2建議 69
參考文獻 71
參考文獻 1. American Water Works Association, C116-09 Protective Fusion-Bonded Epoxy Coatings for the Interior and Exterior Surfaces of Ductile-Iron and Gray-Iron Fittings, 2009.
2. Brater, E. F.; King, H. W., Lindell, J. E. and Wei, C. Y., Handbook of Hydraulics, 7th Edition, McGraw Hill, New York, p. 6.29, 1996.
3. Henry Liu, Pipeline engineering, CRC Press, Taylor & Francis Group, 2003.
4. M. C. Potter and D. C. Wiggert著,吳順治譯,流體力學,東華書局,1995年。
5. Moody, L. F. (1944), "Friction factors for pipe flow", Transactions of the ASME, 66 (8): 671–684.
6. Richard. H. F. Pao著,黃丕陵譯,流體力學,曉園出版社,2006年。
7. 中華民國自來水協會,自來水設備工程設施標準解說,1995。
8. 日本水道協會,水道設施設計指南,2012年。
9. 水利署,自來水工程設施標準,2003年。
10. 水利署,自來水技術人員管理類技術知識概要,2014年。
11. 台灣自來水公司,南區工程處編印,屏東縣潮州鎮供水工程計畫,2014年。
12. 吳世紀,「自來水管線工程規劃設計理論與實務」,自來水會刊,第37 卷,第2 期,2018年。
13. 時佳麟、許敏能、黃欽玲、張正忠、呂紹禎、宋奕潁,「自來水配水管材選用策略之研究」,自來水協會,2018年。
14. 黃欽稜,水理分析介紹與應用, 2015年。
15. 臺北自來水事業處工程總隊,配水管工程設計標準,2003年。
16. 駱尚廉,楊萬發著,自來水及下水道工程,曉園出版社,1991年。
論文全文使用權限
  • 同意授權校內瀏覽/列印電子全文服務,於2024-08-01起公開。
  • 同意授權校外瀏覽/列印電子全文服務,於2024-08-01起公開。


  • 如您有疑問,請聯絡圖書館
    聯絡電話:(06)2757575#65773
    聯絡E-mail:etds@email.ncku.edu.tw